Skip to main content
ESCOM ENHANCED SOLUTIONS

Meet STeaM‑es Dual

STeaM-es Dual

Dual‑sensor accuracy for steam pipes & collectors: Zero‑cable, zero‑battery, zero‑false‑alarms.

Explore STeaM‑es Dual
ESCOM ENHANCED SOLUTIONS

STeaM-es Dual

STeaM-es Dual provides professional, cable‑less acoustic monitoring for main steam lines and condensate collectors with dual sensors, eliminating false alarms and ensuring precise fault detection.

Dual‑Way Detection

Simultaneously captures acoustic data upstream and downstream, delivering 100 % fault certainty while filtering pipe‑side noise.

Thermal Energy Harvesting (TEG)

Harvests waste heat from high‑temperature steam lines to power the sensor, eliminating batteries and maintenance.

Wide‑Area Connectivity

Transmits data from remote collectors via BLE to the Wi‑GaTe gateway, then to the ESCOM‑es dashboard.

Plug‑and‑Play Installation

Snap‑on pipe clamps work on live lines, no shutdown required, even in hard‑to‑reach locations.

02
THE RISK OF SINGLE‑POINT MEASUREMENT

Misleading Acoustic Noise

Single‑sensor systems mistake pump, valve or ambient noise for steam‑leak signatures, generating costly false positives.

Critical Distribution Losses

Undetected leaks in main steam lines and collectors waste massive energy and increase emissions.

Water‑Hammer Threats

Condensate buildup can trigger water‑hammer, threatening pipe integrity and causing unplanned shutdowns.

03
DUAL‑SENSOR, ZERO‑FALSE‑ALARMS

Two Sensors, One Absolute Decision

STeaM‑es Dual compares upstream and downstream acoustic signatures in real‑time, confirming a fault originates from the steam trap, not surrounding equipment.

Self‑Powered by Steam Heat

Thermoelectric harvesting supplies all power needs, removing batteries and wiring for autonomous operation.

04
SUSTAINABLE DISTRIBUTION

Data‑Driven Predictive Maintenance

Dual acoustic data feeds a cloud analytics engine, turning reactive repairs into scheduled, cost‑saving interventions.

Cut fuel costs, extend equipment life, and advance toward carbon‑neutral operations.

05
TECHNICAL SPECIFICATIONS

System Advantages

01
Power Source
Thermoelectric Harvester (Battery‑less)
02
Internal Sensors
Dual Acoustic Profiler & PT1000 Temperature
03
Communication
BLE
04
RF Power
+8 dBm
05
Operating Temperature
-40 °C to +250 °C
06
Measurement Range
-40 °C to +350 °C
07
Power Consumption
750‑950 µW
08
Sampling Speed
2‑4 s
09
Mounting Compatibility
Dual Pipe‑Clamp (customizable)
10
IP Rating
IP68 (Industrial sealed)

Eliminate Steam Pipe Leaks Today

Turn hidden energy losses into savings with STeaM‑es Dual.

Product Integration

Frequently Asked Questions

Standard sensors listen at a single point. Dual‑sensor captures upstream and downstream acoustic data, filtering out ambient noise and guaranteeing fault certainty.

Yes. The snap‑on pipe‑clamp works on live lines, eliminating downtime.

The IP68 enclosure protects against rain, dust, and extreme temperatures, ensuring years of autonomous operation.

Acoustic and temperature data stream via BLE to the ESCOM‑es Dashboard and can be forwarded to SCADA, ERP or BMS platforms.

Typical installations recover $720‑$2,640 per trap per year, achieving ROI in less than a year.